STANDBY POWER · GENERATOR SERVICE

Generator maintenance software that knows every unit at every site down to the NFPA-110 due date.

The platform built for the generator service contractor — not the facility owner, not the OEM portal. Customer → Site → Generator → ATS as first-class records, the NFPA-110 weekly / monthly / annual cadence auto-generated per unit, dispatch by Generac / Kohler / Cummins certification tier, and the multi-day install lifecycle with permit gates — all on one record.

Book a 15-minute callWe will spin up your Customer → Site → Generator → ATS model on the call.
4.8Capterra

Trusted by service contractors who keep the lights on
from single-truck Generac dealers to multi-site Cummins shops.

EGSA-certifiedGenerac PowerProKohler AuthorizedCummins Power GenHospital K-TagData center

01  The standby-power data model

Every generator, every site, on one record — down to the NFPA-110 due date.

Most FSM tools treat a generator like a job line item. FieldCamp models it as a Generator as a Serviced Asset manufacturer, serial, kW, voltage, and OEM warranty expiry on one record.

Beneath it, the Automatic Transfer Switch, fuel tank, and battery live as nested custom objects, not a generic Equipment row. The generator record shows each role its own layout, and the OEM warranty Cummins, Generac, Kohler — sits on the record with the startup PDF. Run hours aren't native; they ride along as a custom field.

Mercy Regional Medical Center
Site asset graphsite_profile

Building C · Mercy Regional

1840 Caregiver Drive · Springfield IL

Active
Hospital · NFPA-992 generatorsK-Tag binder
Generator B-2 · Cummins QSB7250 kW diesel · 480V 3φ · NFPA-110 L1Due Sep 14
ATS-B2 · UL 10081000A · Bypass-IsolationGood
Fuel Tank · sub-base1,500 gal · dieselGood
Battery · Group 31CCA 950 · last 2026-02-14Good
Block heater1.5 kW · verifiedGood
NFPA-110 · Gen B-2 cadenceper-unit
Weekly visual · nextAug 18
Monthly 30/30 · nextAug 22
Annual load bankFeb 14, 2027
Warranty expiryJun 12, 2027
Run hours 1,847 · 2,000hr threshold ahead
Recordgenerator

Generator B-2 · Building C

Mercy Regional · Cummins QSB7 250 kW

Due Sep 14
OverviewVisitsFormsWarranty
Nameplate · custom fields · warranty8 sections
ManufacturerCummins
ModelQSB7-G5
SerialCPGM-7841
kW · Voltage250 kW · 480V 3φ
Install2022-06-12
Run hours · custom1,847Due soon
Last load bank2026-02-14 · 25/50/75%
NFPA-110 levelLevel 1
OEM warrantyCummins · 5yr / 2,000hrDue soon
Service planAnnual NFPA-110 PMActive
Wet-stacking risk · 3mo of <30% monthly load

Custom field flags chronic low-load runs — escalate to annual load bank ahead of schedule.

Run hours crossed 2,000hr — schedule the 2,000hr PMI before Jun 2027 warranty expiry?

Customer → Site → Generator

Generator as a Serviced Asset, explicitly named in the electrical data-model docs — manufacturer, model, serial, kW, voltage, install date, OEM warranty expiry on the record itself.

ATS as its own object

Transfer Switch is a nested custom object — UL 1008 rating, amperage, install date, last thermal scan — not jammed onto a generic Equipment row.

NFPA-110 status is a field

Per-generator NFPA-110 Level (1 or 2), last load bank, run hours (custom field — Equipment does not natively track hours), and next-due cadence row live on the record.

OEM warranty on the unit

Cummins 5yr/2,000hr, Generac 5yr, Kohler 5yr — provider, plan type, coverage, expiry, attached startup PDF on the Warranty record. Alerts wire through Workflows.

02  NFPA-110 cadence, built into the unit

Weekly, monthly 30/30, semi-annual, and annual load bank — auto-generated per generator.

NFPA-110 Chapter 8 is a four-cadence treadmill — weekly visual, monthly 30-minute exercise at 30% load, semi-annual PM, annual two-hour load bank. FieldCamp's Recurring Jobs engine auto-generates every one, per generator.

Each visit runs on a Job Form with required photos and a signature gate — auto-attached to the Generator PM Job Type — and guardrails stop the tech from closing until every field is captured. No one-click NFPA-110 report button — the signed PDFs in the per-site Drive folder become your binder.

Cadence configurator
NFPA-110 cyclerecurring_jobs

Weekly visual check

Every Monday · 15 min

Next

Aug 18

Monthly 30/30 exercise

30 min @ 30% load · every 30 days

Next

Aug 22

Semi-annual PM

Oil + filters + battery + ATS thermal · every 6mo

Next

Oct 12

Annual load bank

25/50/75% step · 30/30/60 min · 2 hrs total

Next

Feb 14, 2027

Job Type: Generator PM auto-attaches NFPA-110 forms + bundle.
NFPA-110 Annual Load Bank
Required checklistjob_forms

*Block heater verified

Toggle · required

Yes

*Coolant level checked

Toggle · required

Good

*Battery CCA recorded

Number · required

*Load bank · 25% · 30min

Number · required

62.5 kW

*Load bank · 50% · 30min

Number · required

125 kW

*Load bank · 75% · 60min

Number · required

187.5 kW

*Photo · nameplate

Photo · required

Attached

*Photo · digital readout

Photo · required

Attached

*Tech signature

Sig pad · required

M. Torres

*Customer sign-off

Sig pad · required

Cannot mark Complete · 2 required fields outstanding (CCA, sign-off).
October · 14 sites · auto-generated

Oct 5

Mercy B-2

Wk-vis

Oct 6

Mercy B-1

Wk-vis

Oct 7

Tower 3

Mo 30/30

Oct 8

Cold Strg

Semi-A PM

Oct 9

Oct 12

Mercy B-2

Semi-A PM

Oct 13

Tower 5

Mo 30/30

Oct 14

Telecom S

Wk-vis

Oct 15

Telecom N

Wk-vis

Oct 16

Data Ctr

Ld bank

Oct 19

Mercy B-2

Wk-vis

Oct 20

Mercy B-1

Wk-vis

Oct 21

Tower 3

Wk-vis

Oct 22

Mercy B-2

Mo 30/30

Oct 23

Tower 5

Wk-vis

Weekly visualMonthly 30/30Semi-annual PMAnnual load bank
Mercy B-2 monthly 30/30 due in 6 days — added to Mike Torres Tuesday route.

03  The install project, phase by phase

From site survey to AHJ wet-witness — every phase, every permit, on one job.

A standby generator install is a multi-week, permit-gated project — survey to pad pour to AHJ wet-witness. FieldCamp wires the whole sequence as a multi-day job separate visits per phase, one parent record.

The Permit object lists Generator as a type with an Applied → Approved → Inspection → Closed lifecycle, and stage guardrails make the wet-witness step a real gate, not a hope — no placard photo and AHJ signature, no Closed. Job Types save the install template, all on the request → estimate → job → invoice backbone.

INSTALL: Generator B-2 · Mercy Regional
Phase timelinemulti_day_jobs
  1. Survey & Load Calc

    Done

    May 02 · S. Lin

  2. Permit · Mechanical

    Approved

    May 19 · AHJ

  3. Permit · Electrical NEC 700

    Approved

    May 19 · AHJ

  4. Gas line rough-in

    Done

    May 22 · S. Lin

  5. Pad pour + 7-day cure

    Done

    May 23 · Crew

  6. Generator delivery

    Done

    Jun 01 · M. Torres

  7. 7

    Electrical rough-in

    In progress

    Jun 12 · M. Torres

  8. 8

    ATS install

    Up next

    Jun 16 · M. Torres

  9. 9

    Commissioning startup

    Up next

    Jun 19 · M. Torres

  10. 10

    AHJ wet-witness

    Scheduled

    Jun 22 · AHJ + M.T.

  11. 11

    Warranty registration

    Up next

    Jun 23 · Office

  12. 12

    Handoff to PM

    Up next

    Jul 01 · Dispatcher

ELEC-2401-882
Permit recordpermits
AHJCity of Springfield
TypeGenerator
Fees$1,420 · paid
Applied2026-05-02
Approved2026-05-19
Inspection due2026-06-22 · wet-witness
Documentstamped_plans.pdf
Stage guardrail · cannot close without
Photo of placard
AHJ signature
Commissioning report PDF

1 of 3 captured · stage stays Open until AHJ-signed commissioning lands.

Pad cure completes Wed — auto-scheduled delivery for Thu 8am with Cummins truck.

04  The OEM warranty channel, untangled

Generac, Kohler, Cummins, Briggs — one record per claim, four portals out.

Generac PowerPro, Cummins Care, Kohler OnCue — every OEM has its own portal, and FieldCamp doesn't replace any of them. It organizes the claim packet on the unit: a Warranty record with provider, plan, dates, and the startup PDF.

A Workflow fires 30 days before expiry — a documented pattern — to email the customer and draft the renewal. Hierarchical skill matching puts only Cummins-certified techs on Cummins claims, and the photos, claim form, and RMA live in the site's Drive folder, AI-searchable. Portal submission still happens in the OEM's app.

Warranty record
OEM warrantywarranties
ProviderCummins
Plan typeManufacturer
CoverageParts + Labor
Length5 yr OR 2,000 hr (whichever first)
Start2022-06-12
End2027-06-12
Claim statusDraft

Attached files · 4

warranty_startup_2022.pdf
claim_form.pdf
photo_serial.jpg
photo_nameplate.jpg
Warranty expiry · 30-day pre-alert
Recipeworkflows

Trigger

warranty.end_date − 30 days

Conditions

Generator.type = Standby AND Run hours < 2,000

Actions · 3

Email customer

template: "Cummins warranty expires Jun 2027 — renew with our 5-yr extended plan"

Create renewal Estimate

from bundle: Cummins Extended Coverage

Add task to dispatcher queue

owner: dispatch group

OEM certification routing matrix
Certification by brandhierarchical_skills
TechGeneracKohlerCumminsBriggs
Mike TorresL3L2L3
Sarah LinL2
Diego RamosL2L1
Aliya KhanL3

Cummins claim on Gen B-2 → only Mike (L3) or Diego (L2) are eligible. Warranty work routed by hierarchical skills.

Cummins warranty expires in 343 days — renewal estimate $3,840 drafted from bundle Cummins Extended Coverage.

05  Outage Night

Storm hits, ATS A1 transfers — and the on-call mechanic is already inbound.

When Generator B-2 picks up Mercy's critical loads, the call lands in the unified inbox — phone, SMS, or forwarded CMMS email. The AI Dispatcher ranks on-call mechanics by Cummins cert level, distance, and load.

Drew, the L3, is paged with a 1-tap ETA link — Mercy facilities watch his truck cross the city.

Outage event · 2026-04-18 22:47 CDT

Active
22:47ATS A1 transferred to Generator B-2 (utility loss)
22:48Inbox: SMS from Mercy facilities → Request created
22:49AI Dispatcher → Drew (Cummins L3, 14 mi away)
22:50ETA link sent to Mercy facilities · 38 min
22:54Drew accepted · departing service center

06  On the pad

NFPA-110 inspection form on the tablet — even in a basement utility room.

Drew completes the NFPA-110 inspection checklist on his tablet — runtime hours, exhaust temp, battery, fuel level, ATS transfer test. Run hours are logged manually.

The form works offline in Mercy's basement utility room and syncs when he climbs back up — every reading, photo, and signature lands on Generator B-2's service history.

NFPA-110 monthly inspection · Generator B-2 · 2026-04-18

Runtime hours (manual)847.3 hrs
Exhaust temp (after stack)642 °F
Coolant levelFull · no leaks
Battery electrolyteOK · 12.6 V
Fuel level (diesel)92%
ATS A1 transfer testPass · 14s
Ground continuity0.4 Ω
30-min load run @ 30% nameplatePass

07  Failed ATS · multi-option quote

Repair, refurbish, or replace — customer e-signs in 90 seconds.

ATS A1 fails its monthly transfer test. Drew opens an estimate with three options repair, refurbish, or replace — pre-priced from the pricebook.

Mercy facilities e-approves Option B via digital signature, and the refurb Job auto-creates for next Tuesday.

Repair contactor

$ 2,140

Replace pole, recommission

Declined

Refurbish (recommended)

$ 8,920

Bypass module + 5-yr coverage

✓ Approved · e-signed

Replace with ASCO 7000

$28,400

New ATS + 10-yr coverage

Approve

08  The PM flywheel

Weekly, monthly, semi-annual, annual — NFPA-110 cadence auto-scheduled.

Every standby generator runs a published cadence — weekly visual, monthly exercise, semi-annual fluids, annual load bank. FieldCamp's Recurring Jobs auto-generates each Visit on the right cadence.

When a visit completes, the next one auto-schedules — no spreadsheet, no missed PM, no NFPA gap at the next AHJ inspection.

Weekly

Next: Mon Apr 22

Visual + battery test

Monthly

Next: May 18

30-min exercise @ 30% load

Semi-annual

Next: Oct 14

Oil + coolant + filters

Annual

Next: Apr 2027

2-hour load bank @ 100%

09  Storm surge

200 generators hit at once — triage, dispatch, contain.

A regional outage drops 200 standby generators into emergency duty across BlueRoad's 9-site portfolio. Facility-CMMS calls aggregate in the Inbox via email forwarding.

The Command Center triages by SLA tier — hospitals first — routes by service area, and lights up the dispatch board across every available tech, back-up bench included.

Tier-1 · Hospitals

7 sites

SLA · ≤ 30 min

Tier-2 · Commercial

31 sites

SLA · ≤ 2 hr

Tier-3 · Residential

162 sites

SLA · Within 24 hr

Dispatch board auto-assigns by tier; back-up bench called in via the Command Center.

10  Portfolio view

One BlueRoad account, 9 sites, 80 generators — one record set.

Legacy FSM tools force "one customer per site." FieldCamp's Customer → Site → Asset hierarchy holds one BlueRoad parent with 9 child sites, each carrying its own assets.

The multi-location data model rolls revenue, AR, and PM compliance up to portfolio level — and into a customer portal facility ops can self-serve from.

BlueRoad Properties · portfolio rollup

Sites

9

Generators

80

ATS

112

PM on-cadence

97.4%

11  Capabilities

Everything a generator service contractor runs on — on one platform.

From outage-night dispatch to the NFPA-110 PM flywheel to the OEM warranty channel — with the AI Command Center answering portfolio questions in plain English.

Field & dispatch

  • Cert-gated dispatch via Hierarchical Skills (Cummins L1/L2/L3, Generac Pro, Kohler Cert)
  • On-call rotation + outage-night dispatch
  • Offline mobile inspection forms (basement-proof)
  • GPS-tagged Visits + ETA links to facility ops

NFPA-110 lifecycle

  • Weekly / monthly / semi-annual / annual cadence auto-scheduled
  • Custom inspection form (NFPA-110 checklist) per Visit
  • Manual runtime-hours capture on every Visit
  • Auto-attach inspection PDF + retention in Files & Drive

Multi-OEM warranty

  • Custom Warranty object (Generac / Cummins / Kohler / OEM portal URL)
  • RMA tracking with claim # field
  • Warranty expiry surfaced on Generator record
  • Workflow Automation alerts N days before expiry (if wired)

Billing & multi-site

  • Customer → Site → Asset hierarchy (one portfolio, many sites)
  • Recurring MSA billing + Stripe Pay Now link
  • QuickBooks Online / Xero / Wave sync
  • Multi-day install jobs (excavation → set → commissioning)

12  Why it matters

Three reasons generator contractors switch. And stay.

01

NFPA-110 is the contract.

Lose PM cadence and the AHJ flags it on the next inspection — and Joint Commission flags it on the next hospital survey. FieldCamp's recurring cadence engine keeps every generator on its weekly / monthly / semi-annual / annual loop, with the inspection form auto-attached.

02

The OEM warranty channel is the upsell.

Generac, Cummins, Kohler each have their own portal, claim format, and reimbursement timeline. FieldCamp logs the channel + claim # on the Generator + Warranty record so your tech files the RMA in the right portal — and your bookkeeper tracks the reimbursement.

03

Multi-site portfolios are a different shape.

One BlueRoad Properties account, 9 sites, 80 generators, 112 ATSes. The Customer → Site → Asset hierarchy + multi-location data model rolls revenue, AR, and PM compliance up to the portfolio without forcing one-customer-per-site hacks.

14  FAQ

Common questions generator contractors ask.

Generator maintenance software is the system of record a generator service contractor uses to manage every standby and prime-power generator under contract — from the unified inbox at outage-night through cert-gated dispatch, NFPA-110 inspection cadence, OEM warranty channel tracking (Generac / Cummins / Kohler), failed-ATS quoting, multi-day install jobs, and recurring MSA billing. FieldCamp ties Property → Generator → ATS into one record set so the contract, the cadence, the channel, and the customer portal all live in one platform.

NFPA-110 Chapter 8 requires a monthly 30-minute exercise at a minimum of 30% nameplate load (else an annual two-hour load bank @ 100%). FieldCamp uses Recurring Jobs at monthly cadence with a custom NFPA-110 inspection form auto-attached to the Visit. The technician logs runtime hours manually, completes the form, signs off — and the PDF is retained on the Generator record in Files & Drive.

Honestly: we don't directly post into Generac PowerPro, Cummins Care, or Kohler OnCue — those portals still need their own login. What FieldCamp does is log the channel + claim # as fields on a Warranty custom object linked to the Generator. The tech files the RMA in the OEM portal; FieldCamp tracks the channel, the date, the reimbursement timeline, and surfaces it on the Generator's warranty card.

No — those are telemetry platforms, and they stay in their own lane. FieldCamp is the dispatch, scheduling, NFPA-PMI, and billing platform that sits on top. Most contractors store the OEM telemetry portal URL as a link field on the Generator record so the tech can one-tap into the live readings during a PM visit.

Yes. The install runs as a Multi-Day Job (excavation Day 1 → set Day 2 → commissioning + AHJ wet-witness Day 3+). Permits (generator + transfer-switch permits are explicitly listed in the docs) attach as a custom Permits object to the install Job, each with permit number, AHJ, fees, and Applied → Approved → Inspection → Closed lifecycle.

Yes. Per the using-forms-in-the-field-mobile-guide, the field forms work offline — every reading, photo, signature, and Job Log entry is captured locally and syncs the moment the device gets bars back. Tested in basements and underground utility vaults.

The Customer → Site → Asset hierarchy (same shape documented for commercial-hvac) holds the portfolio parent customer with N child sites, each carrying its own assets. The multi-location data model rolls revenue, AR, PM compliance, and dispatch coverage up to the portfolio level — without forcing one-customer-per-site hacks.

A Service Agreement (modeled as a custom object) holds the standing PM-plan terms; Recurring Jobs auto-generates the Visits on cadence; the invoice generates per visit (or rolls up monthly) with auto-charge on the customer's card on file via Stripe. QuickBooks Online / Xero / Wave bidirectional sync pushes every entry — no double-keying.

Get started

Want generator software built around your service yard?

Fifteen minutes. We'll spin up your NFPA-110 cadence, your Cummins/Generac/Kohler skill map, and your portfolio rollup on the call.